Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mater Horiz ; 10(9): 3631-3642, 2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37337936

RESUMO

In this study, we demonstrate the sintering of metastable ε-Fe2O3 nanoparticles into nanoceramics containing 98 wt% of the epsilon iron oxide phase and with a specific density of 60%. At room temperature, the ceramics retain a giant coercivity of 20 kOe and a sub-terahertz absorption at 190 GHz inherent in the initial nanoparticles. The sintering leads to an increase in the frequencies of the natural ferromagnetic resonance at 200-300 K and larger coercivities at temperatures below 150 K. We propose a simple but working explanation of the low-temperature dynamics of the macroscopic magnetic parameters of the ε-Fe2O3 materials via the transition of the smallest nanoparticles into a superparamagnetic state. The results are confirmed by the temperature dependence of the magnetocrystalline anisotropy constant and micromagnetic modeling. In addition, based on the Landau-Lifshitz formalism, we discuss features of the spin dynamics in ε-Fe2O3 and the possibility of using nanoceramics as sub-terahertz spin-pumping media. Our observations will expand the applicability of ε-Fe2O3 materials and promote their integration into telecommunication devices of the next generation.

2.
Anal Chem ; 95(19): 7528-7535, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37129422

RESUMO

We propose pulse power generation (PPG) amperometry as an advanced readout realized for Prussian blue (PB)-based (bio)sensors. In contrast to the conventional power generation mode, when the current response is generated upon continuous short-circuiting, the suggested pulse regime is fulfilled by periodic opening and shorting of the circuit. Despite PB being electroactive, the pulse readout is advantageous over conventional steady-state power generation, providing up to a 15-fold increased signal-to-background ratio as well as dramatically improved sensitivity exceeding 10 A·M-1·cm-2 for H2O2 sensors and 3.9 A·M-1·cm-2 for glucose biosensors. Such analytical performance characteristics are, most probably, achieved due to the enrichment of the diffusion layer by analyte mass transfer from the bulk upon opening of the circuit. Due to an improved sensitivity-to-background ratio, reduced flow-rate dependence, and enhanced operational stability, the regime allows reliable monitoring of blood glucose variations through sweat analysis with the on-skin device.


Assuntos
Técnicas Biossensoriais , Diabetes Mellitus , Humanos , Peróxido de Hidrogênio , Glucose , Glicemia , Diabetes Mellitus/diagnóstico
3.
Biosens Bioelectron ; 227: 115148, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36841113

RESUMO

Despite non-invasive instant monitoring of sweat metabolites is becoming a general trend in early diagnostics and screening, the reliability and accuracy of the on-skin electrochemical biosensors in real-life scenarios still remain questionable. As a rule, mass transport effects in scantily excreted liquids are ignored, when considering the design of such wearable setups. Here we provide a comprehensive investigation of the disruption factors for commonly used Prussian Blue based (bio)sensors under different hydrodynamic conditions (2 × 10-5 - 5 × 100 mm s-1 electrolyte velocity). A huge effect of flow on the (bio)sensors response has been revealed and explained with transport limitations for both analyte influx and reaction product outflux. It suggests no need for improving the sensor sensitivity, while minimizing analyte consumption and enhancing product withdrawal. Some strategies concerning measurement schemes and sensor design ensuring reliable sweat analysis have been discussed and illustrated for lactate and glucose on-skin monitoring.


Assuntos
Técnicas Biossensoriais , Líquidos Corporais , Dispositivos Eletrônicos Vestíveis , Reprodutibilidade dos Testes , Líquidos Corporais/química , Glucose/análise , Suor/química
4.
Biosens Bioelectron ; 202: 113970, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35032921

RESUMO

We report on the simultaneous monitoring of sweat lactate concentration and sweat secretion rate. For this aim lactate oxidase-Prussian Blue enzyme-nanozyme type lactate biosensors were elaborated. The use of siloxane-perfluorosulfonated ionomer composite membrane for enzyme-nanozyme immobilization results in the biosensor displaying flux independence in the whole range of physiological sweat secretion rates (0.025-2 µl cm-2 min-1). On the contrary, current response of the biosensor based on solely siloxane membranes becomes saturated at physiological sweat lactate concentration, depending mostly on the flow rate. Accordingly, for simultaneous monitoring of sweat lactate concentration and its secretion rate both flow-through biosensors were integrated with high-accuracy wearable electronic devices allowing real-time remote monitoring. As found, during exhaustive physical exercise sweat secretion rate and lactate content are independent of each other, thus, confirming that this excretory liquid is suitable for non-invasive diagnostics.


Assuntos
Técnicas Biossensoriais , Ácido Láctico/análise , Suor/química , Dispositivos Eletrônicos Vestíveis , Técnicas Biossensoriais/métodos , Enzimas Imobilizadas , Humanos
5.
Nanomaterials (Basel) ; 11(4)2021 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-33916445

RESUMO

Magnetically hard ferrites attract considerable interest due to their ability to maintain a high coercivity of nanosized particles and therefore show promising applications as nanomagnets ranging from magnetic recording to biomedicine. Herein, we report an approach to prepare nonsintered single-domain nanoparticles of chromium-substituted hexaferrite via crystallization of glass in the system SrO-Fe2O3-Cr2O3-B2O3. We have observed a formation of plate-like hexaferrite nanoparticles with diameters changing from 20 to 190 nm depending on the annealing temperature. We demonstrated that chromium substitution led to a significant improvement of the coercivity, which varied from 334 to 732 kA m-1 for the smallest and the largest particles, respectively. The results provide a new strategy for producing high-coercivity ferrite nanomagnets.

6.
RSC Adv ; 11(12): 6926-6933, 2021 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-35423173

RESUMO

Tb-diluted and Tb-rich apatite-type silicates with compositions Y7.75Tb0.25Ca2(SiO4)6O2 and Tb8Ca2(SiO4)6O2, respectively, exhibit field induced multiple slow relaxation of magnetization. The former reveals two slow relaxation paths, the latter only one with a longer relaxation time of several seconds. The relaxation features of the Tb-diluted one are comparable with those of analogue compounds, where Tb is replaced by Dy, as well as with those of a Tb-doped calcium phosphate apatite. The relaxation parameters of the Tb-rich compound virtually match those of the Dy-based analogue Dy8Ca2(SiO4)6O2. The latter represents the first instance of independence of magnetization relaxation on the nature of a paramagnetic rare-earth metal ion in single ion magnet like materials.

7.
ACS Appl Mater Interfaces ; 13(1): 1592-1602, 2021 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-33355441

RESUMO

Spray deposition is a scalable and cost-effective technique for the fabrication of magnetic hybrid films containing diblock copolymers (DBCs) and magnetic nanoparticles. However, it is challenging to obtain spray-deposited anisotropic magnetic hybrid films without using external magnetic fields. In the present work, spray deposition is applied to prepare perpendicular anisotropic magnetic hybrid films by controlling the orientation of strontium hexaferrite nanoplatelets inside ultra-high-molecular-weight DBC polystyrene-block-poly(methyl methacrylate) (PS-b-PMMA) films. During spray deposition, the evolution of DBC morphology and the orientation of magnetic nanoplatelets are monitored with in situ grazing-incidence small-angle X-ray scattering (GISAXS). For reference, a pure DBC film without nanoplatelets is deposited with the same conditions. Solvent-controlled magnetic properties of the hybrid film are proven with solvent vapor annealing (SVA) applied to the final deposited magnetic films. Obvious changes in the DBC morphology and nanoplatelet localization are observed during SVA. The superconducting quantum interference device data show that ferromagnetic hybrid polymer films with high coercivity can be achieved via spray deposition. The hybrid films show a perpendicular magnetic anisotropy before SVA, which is strongly weakened after SVA. The spray-deposited hybrid films appear highly promising for potential applications in magnetic data storage and sensors.

8.
Nanoscale ; 11(20): 9980-9986, 2019 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-31074468

RESUMO

Here we report on the spontaneous assembly of Ti3C2Tx MXene flakes into monolayer films at the liquid-air interface. According to X-ray reflectivity and grazing incidence X-ray fluorescence both the structure of the layers and assembly kinetics depends on the pH value of the solution. At pH > 4 MXene flakes form a single ∼1.5 nm thick layer carrying a negative charge, while in the acidic medium the layer contains coordinated anions with the formation of the Braq-/Ti3C2Tx/subphase interface. The surface layer compression allows the assembling of MXene flakes into a dense monolayer films with the surface coverage of up to 96% and surface pressure exceeding 40 mN m-1 in the case of the acidic subphase. The films can readily be transferred onto solid substrates by the conventional Langmuir-Blodgett approach or modified by surfactants to form MXene/surfactant composite films.

9.
Chem Commun (Camb) ; 53(39): 5416-5419, 2017 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-28453011

RESUMO

An apatite-type barium phosphate with a high content of cobalt ions in the trigonal channels features slow relaxation of magnetization with an energy barrier Ueff of up to 387 cm-1, which is well above the values for all so far known d-metal based single-molecule magnets (SMMs).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...